SPECIFICATIONS
MODEL UDC9110H One
Capacity (VA/Watts) 10K/10KINPUT
Nominal Voltage 220/230/240VacOperating Voltage range 120~276VacFrequency range 50Hz:45~55Hz; 60Hz:54~66Hz (auto sensing)Power Factor ≥0.99Bypass voltage range Max. voltage: 220V: +25% (optimal +10%, +15%, +20%)230V: +20% (optimal +10% +15%)240V: +15% (optimal +10%)Min. voltage: -45% (optimal -20%, -30%)Bypass frequency range Frequency protection range: ±10%ECO range Same as the bypassHarmonic distortion (THDi) <3% (100% linear load)Generator input SupportOUTPUT
Output Voltage 220/230/240VacPower Factor 1Voltage Regulation ±1%FrequencyLine mode (Synchronized range) ±1%/ ±2%/ ±4%/ ±5%/ ±10% of the rated frequency (optimal)Bat. mode (50/60±0.1) HzCrest Factor 3:1Harmonic Distortion (THDv) ≤2% with linear Load≤ 5% with non-linear loadEfficiency >93%BATTERY
Battery voltage ±96/108/120Vdc (optimal)Capacity (standard unit) 12V-7Ah/9AhTypical recharging time 6~8 hours (to 90% of full capacity)Charging current 1A (Standard unit); Long run unit Max. current 10A (charging current can be set according to batterycapacity installed)SYSTEM FEATURES
Transfer time Mains to battery: 0ms; Mains to bypass: 0msOverloadLine Mode Load ≤110%: last 10min, ≤130%: last 1min, >130% turn to bypass mode immediatelyBypass Mode 80A(Breaker)Short circuit Hold whole systemOverheat Line mode: Turn to bypass; Bat. Mode: Shut down UPS immediatelyBattery low Alarm and switch offSelf-diagnostics Upon power on and software controlBattery Advanced battery managementAudible & Visual alarms Line failure, Battery low, Over load, System faultLED & LCD display Line mode, Bat. mode, Eco mode, Bypass mode, Battery under voltage, Overload 1 UPS faultLCD display Input voltage, Input frequency, Output voltage, Output frequency, Load percentage, Battery voltage,Inner temperature & Remaining battery backup timeCommunication interface RS232, USB, SNMP card(optional), Parallel card(optional), Replay card (optional)ENVIRONMENT
Operating temperature 0°C~40°CStorage temperature -25°C~55°CHumidity range 0-95% (non-condensing)Altitude <1500mNoise Level <55dBPHYSICAL
Dimension W×H×D (mm) Standard model: 191*460*720; long run model: 191*405*330Net Weight (kg) Standard model: 61kg; long run model: 12kgSTANDARDS
Safety IEC/EN62040-1,IEC/EN60950-1EMC IEC/EN62040-2,IEC61000-4-2,IEC61000-4-3,IEC61000-4-4,IEC61000-4-5,IEC61000-4-6, IEC61000-4-8 - Revues du produit